Call Now

Commercial Air Conditioning Installation in Geelong – Eden Oak Project Case Study

Commercial air conditioning installation case study presentation for a project completed near Melbourne

Daikin Ceiling Suspended Air Conditioning Installation at Eden Oak, East Geelong

Comfyhome recently completed a commercial air conditioning installation in East Geelong at the beautiful Eden Oak venue located near the Geelong Botanic Gardens.

This project involved the installation of a Daikin ceiling suspended refrigerated air conditioning system designed to provide powerful cooling, improved airflow distribution, and modern electrical safety compliance for the venue.

The property required both a HVAC upgrade and an electrical infrastructure improvement, as the existing fuse-based switchboard was outdated and unsuitable for modern commercial equipment.

After five days of installation and commissioning, the venue now benefits from efficient cooling performance, improved comfort, reduced power consumption, and a fully compliant electrical system.

PROJECT SUMMARY

Location:
Eden Oak Geelong
20 Adams Ct, East Geelong VIC 3219
(Near Geelong Botanic Gardens)

Property Type:
Single-storey commercial venue

Daikin ceiling suspended refrigerated air conditioning system installed for the Eden Oak commercial project in East Geelong

System Installed:
Daikin Ceiling Suspended Refrigerated Air Conditioning System

  • Indoor Unit: FHA140CVMA
  • Outdoor Unit: RZAV140F2V1

Installation Duration:
5 days

Special Requirement:
Commercial electrical switchboard upgrade

This installation was designed to deliver reliable cooling performance for a large open interior space while maintaining the aesthetic of the venue’s timber ceiling architecture.

About the Eden Oak Venue

Eden Oak is a beautiful event and hospitality venue located in East Geelong, close to the well-known Geelong Botanic Gardens.

The building features:

  • Large open dining and event spaces
  • High ceilings with exposed timber panels
  • Extensive glass windows allowing natural light
  • Multiple seating and lounge areas

These architectural features create a welcoming environment but also present cooling challenges, particularly during hot Geelong summer temperatures.

Large open interiors combined with high ceilings require powerful airflow and strategic air distribution to maintain consistent comfort.

Interior dining area with ceiling mounted air conditioning unit installed at Eden Oak in East Geelong

THE CHALLENGE

Before the upgrade, the property had two major issues that needed to be addressed.

1. Outdated Fuse-Based Electrical Switchboard

One of the most critical problems discovered during the initial site inspection was the existing fuse-based switchboard.

This type of electrical system is considered outdated and unsafe for modern commercial buildings.

Problems with Fuse-Based Switchboards

Older fuse boards present several risks:

  • Lack of modern electrical protection
  • Limited load capacity for commercial HVAC systems
  • Higher risk of overheating and electrical faults
  • Non-compliance with current electrical standards
  • Difficulty in maintenance and replacement

Modern commercial air conditioning systems require stable electrical supply and proper circuit protection.

Before installing the Daikin air conditioning system, the building required a complete commercial switchboard upgrade to ensure electrical safety and compliance.

2. Cooling Requirements for Large Open Spaces

The venue contains several open areas used for dining, events, and gatherings.

The layout includes:

  • Large seating areas
  • Open bar and service spaces
  • Lounge areas
  • A studio space converted from a garage

Cooling such a layout requires high airflow capacity and effective air distribution.

Standard wall-mounted systems would not provide sufficient coverage for this type of commercial space.

Instead, a ceiling suspended air conditioning system was selected as the ideal solution.

Installation scaffold setup beneath ceiling during air conditioning works at Eden Oak in East Geelong

Why We Chose a Daikin Ceiling Suspended Air Conditioning System

For this project, the Comfyhome team selected the Daikin FHA140CVMA ceiling suspended system paired with the RZAV140F2V1 outdoor unit.

Daikin is one of the most trusted HVAC manufacturers in Australia and is known for:

  • High energy efficiency
  • Reliable cooling performance
  • Commercial-grade durability
  • Advanced inverter technology

The ceiling suspended system was chosen for several reasons.

Ideal for Buildings Without Ceiling Cavities

Many commercial buildings with exposed architectural ceilings do not have sufficient ceiling space for concealed ducted systems.

Ceiling suspended systems provide an excellent alternative because they:

  • Mount directly below the ceiling structure
  • Require minimal ceiling modification
  • Provide strong directional airflow

Powerful Airflow for Large Open Areas

The Daikin FHA series delivers strong airflow capable of cooling large commercial spaces.

This makes it perfect for:

  • Restaurants
  • Event venues
  • Function spaces
  • Studios
  • Hospitality environments

The airflow pattern helps distribute cool air evenly across the room.

Energy Efficient Inverter Technology

The installed system uses Daikin inverter technology, which automatically adjusts compressor speed depending on cooling demand.

This provides several benefits:

  • Lower energy consumption
  • Reduced operating costs
  • Faster cooling response
  • Consistent temperature control

This technology is particularly valuable during hot Australian summers, when air conditioning systems operate for long hours.

Ladders and air conditioning equipment prepared for installation inside Eden Oak venue in East Geelong

The Installation Process

The entire installation was completed over five days, including electrical upgrades and system commissioning.

The process involved several stages.

Stage 1 – Removal of Existing Equipment

The first step was removing outdated equipment and preparing the installation area.

This included:

  • Removing old air conditioning units
  • Preparing mounting locations
  • Assessing electrical supply

Stage 2 – Commercial Electrical Switchboard Upgrade

Before installing the new HVAC system, the team upgraded the building’s electrical infrastructure.

This included installing a modern commercial switchboard with proper circuit protection.

Benefits of the upgrade include:

  • Increased electrical safety
  • Compliance with modern Australian standards
  • Improved reliability for HVAC operation
  • Capacity to support future electrical loads

Stage 3 – Installation of Daikin Indoor Units

The Daikin ceiling suspended indoor units were mounted under the structural timber beams.

The installation was carefully planned to:

  • maximise airflow coverage
  • maintain the venue’s interior design
  • ensure easy future servicing access

The positioning allows cool air to distribute across the open seating areas efficiently.

Stage 4 – Outdoor Condensing Unit Installation

The Daikin RZAV140F2V1 outdoor unit was installed outside the building.

This unit houses the compressor and condenser responsible for heat rejection.

Proper placement of the outdoor unit ensures:

  • efficient heat exchange
  • low operating noise
  • easy service access

Stage 5 – Refrigerant Piping and Electrical Connection

Once both indoor and outdoor units were installed, the team connected:

  • refrigerant pipework
  • electrical wiring
  • communication cables

All refrigerant lines were pressure tested to ensure leak-free operation.

Stage 6 – System Testing and Commissioning

The final step was system commissioning.

This included:

  • vacuuming refrigerant lines
  • charging refrigerant
  • testing cooling performance
  • checking airflow balance
  • verifying electrical safety

After testing, the system was fully operational and ready for use.

Ceiling suspended air conditioning unit installed inside Eden Oak venue in East Geelong

The Result

The completed installation delivered several key improvements for the venue.

Improved Airflow and Indoor Comfort

The new Daikin system delivers strong and consistent airflow across the venue.

Guests and staff now experience comfortable indoor temperatures even during peak summer conditions.

The ceiling suspended design allows cool air to spread evenly throughout the open space.

Reduced Energy Consumption

With inverter technology and modern system design, the new installation operates more efficiently than older systems.

This helps reduce:

  • electricity consumption
  • operational costs
  • energy waste during partial load conditions

For commercial venues operating long hours, this translates into significant long-term savings.

Safer and Fully Compliant Electrical System

The upgraded commercial switchboard ensures the building now meets modern electrical safety standards.

This upgrade provides:

  • safer electrical operation
  • proper circuit protection
  • improved reliability for HVAC equipment

Clean and Professional Installation

The indoor units were installed neatly beneath the timber beams.

This approach:

  • preserves the venue’s interior aesthetics
  • optimises airflow distribution
  • allows efficient use of ceiling space

The result is a professional and visually clean installation that integrates seamlessly into the building design.

Why Commercial Properties in Geelong Choose Ceiling Suspended Air Conditioning

Ceiling suspended air conditioning systems are becoming increasingly popular in Geelong commercial buildings.

They are particularly suitable for:

  • restaurants
  • cafés
  • event venues
  • retail spaces
  • studios
  • hospitality environments

Key Advantages

  • Strong airflow for large spaces
  • Suitable for buildings without ceiling cavities
  • Flexible installation locations
  • Easy maintenance access
  • Reliable cooling performance

For many commercial venues, these systems offer the perfect balance of performance, efficiency, and practicality.

Looking for Commercial Air Conditioning Installation in Geelong?

If your commercial property requires professional air conditioning installation, HVAC upgrades, or electrical switchboard upgrades, Comfyhome can help.

Our experienced team specialises in:

  • Commercial air conditioning installation
  • Daikin air conditioning systems
  • VRF and split system solutions
  • Electrical switchboard upgrades
  • Energy-efficient HVAC upgrades

We work with restaurants, hospitality venues, offices, retail spaces, and commercial properties throughout Geelong and Melbourne.

📍 Servicing Geelong, Melbourne, and surrounding areas

If you’re planning a commercial air conditioning upgrade or new HVAC installation, contact Comfyhome today to discuss your project.

A ONE-STOP SOLUTION For All Your Heating & Cooling Needs